| Technical data |
| |
Laser protection class: |
1 (21 CFR 1040.10 und 1040.11, IEC 60825-1:2001) |
|
| |
Enclosure rating: |
IP 65 (EN 60529) |
|
| |
Protection class: |
2 (DIN VDE 0160, DIN EN 50178) |
|
| |
Ambient operating temperature from ... to: |
-10 ... 50 °C |
|
| |
Dimensions (W x H x D): |
102 x 152 x 105 mm |
|
| |
Weight: |
1.2 kg |
|
| |
Scan angle: |
270 ° |
|
| |
Switching field range: |
10 m |
|
| |
Number of field sets: |
16 |
|
| |
Minimum response time: |
40 ms |
|
| |
Fixed object resolution: |
30 mm, 40 mm, 50 mm, 70 mm, 150 mm, selectable |
|
| |
Variable object resolution: |
10 mm, depending on distance |
|
| |
Electrical connection: |
Plug-in connection housing with screw, Screw-type terminals |
|
| |
Supply voltage: |
16.8 V DC, 24 V DC, 30 V DC |
|
| |
Number of switching inputs: |
4 |
|
| |
Number of switching outputs: |
2 , Q1 and Q2 |
|
| |
Number of application diagnostic outputs: |
2 , "Q1 inverted" and "Q2 inverted" |
|
| |
No. of application diagnostic outputs (error/contamination): |
1 |
|
| |
Maximum output current: |
250 mA |
|
| |
Configuration and diagnostics interface: |
RS-232 |
|
| |
Fieldbus interface: |
CANopen |
|