S3000 Standard, Sensor head with I/O module

Manufacturer

Video

See video
SKU:

Ris_SICK_1028934

S3000 SICK Part No 1028934

  • 4 m protective field range
  • 4 switchable field sets (4 protective fields, 8 warning fields)
  • Configuration memory integrated in the system plug
  • EFI interface for safe SICK device communication
  • Selectable resolution for hand, leg or body detection
  • Simultaneous monitoring of two protective fields
  • Contour as reference for vertical applications
  • Integrated external device monitoring (EDM)
  •  
  • Largest protective field range available on the market increases the variety of application possibilities
  • Safety engineering - with no loss of productivity.
  • Quick recommissioning via configuration memory
  • Easily expandable modular system, simple cabling and additional functions using SICK safety controllers with EFI
  • Easy installation, commissioning and maintenance for stationary and mobile applications
  • Decades of proven safety technology guarantee maximum reliability and productivity - even under difficult conditions
  • Simple alignment and safe operation in vertical mode

S3000 Professional Specifications

Applications
Hazardous area protection (vertical):
Access protection (vertical):
Hazardous area protection (horizontal):


 

Functions
Simultaneous monitoring of two areas:
Static control outputs for switching between warning fields:
Incremental encoder inputs:
External device monitoring:
Integrated configuration memory:
Expanded measured data output (CMS, RS-422): -
Measured data output (RS-422):
Safe device communication via EFI/SDL:


 

Technical data
Laser protection class: 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001)
Enclosure rating: IP 65 (EN 60529)
Protection class: II (EN 50178)
Type: Type 3 (IEC/EN 61496-3)
Safety integrity level: SIL2 (IEC 61508), SILCL2 (EN 62061)
Category: Category 3 (EN ISO 13849)
Performance level: PL d (EN ISO 13849)
PFHd: 8.0 * 1E-08 (EN ISO 13849)
TM (mission time): 20 a (EN ISO 13849)
Ambient operating temperature from ... to: -10 °C ... 50 °C
Dimensions (W x H x D): 155 mm x 185 mm x 160 mm
Weight: 3.3 kg
Scan angle: 190 °
Protective field range: 4 m
Maximum warning field range: 49 m
Number of field sets: 8 1)
Response time: 60 ms, 120 ms 2)
Resolution: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, selectable
Distance measuring range: 49 m
Number of multiple samplings: Configurable via CDS 2 ... 16
Electrical connection: Plug-in connection housing with screw, screw-type terminals
Supply voltage: 16.8 V DC, 24 V DC, 28.8 V DC
Number of EDM inputs: 1
Number of reset-/restart inputs: 1
Number of static control inputs: 4
Number of static control inputs with EFI: 5 3)
Number of dynamic control inputs: 2 4)
Number of safe outputs: 2, Safety outputs (OSSD)
Number of application diagnostic outputs: 3 5)
Maximum output current: 500 mA
Configuration and diagnostics interface: RS-232
Data interface: RS-422
1) 1 field set = 1 protective field and 2 warning fields  2) Depending on basic response time and multiple sampling  3) Via EFI, only in combination with a Flexi Soft safety controller or EFI gateways  4) Two of the static swichting signals can be used either as dynamic or as static switching signals.  5) Freely programmable, e.g., warning field, contamination, reset required