SICK Tim5xx

SICK Tim5xx are the new indoor laser scanners from SICK.  The Tim5xx series has 2 models:

  • SICK TIM551-2050001 (SICK part No: 1062210) and

  • SICK TIM510-9950000S01 (SICK paart No: 1060445)

SICK TIM551-2050001:

  • Max. range with 10 % reflectivity: 2m

  • Field of view: 270°

SICK TIM510-9950000S01:

  • Max. range with 10 % reflectivity: 8m

  • Field of view: 270°

SICK TIM551-2050001 | TIM510-9950000S01

 

 

SICK TIM551-2050001 | TIM510-9950000S01 dimensional drawings

 

SICK TIM551-2050001 | TIM510-9950000S01 scanning range

Blog

Comparison of SICK LMS100, SICK LMS500, SICK TIM310 and SICK S100

SICK LMS100, SICK LMS500, SICK TIM310 and SICK S100 are all indoor scanners with differrent scanning ranges.  Below you can see their differences:

  SICK LMS100 SICK LMS500 SICK TIM310 SICK S100
Version Short Range Mid Range Short Range Short Range
Light source Infrared (905 nm) Infrared (905 nm) Infrared (850 nm) Infrared (905 nm)
Laser Class 1 (IEC 60825-1 (2007-3)) 1 (IEC 60825-1 (2007-6)), eye-safe 1 (IEC 60825-1 (2007-10)) eye-safe 1 (21CFR 1040.10, 21CFR 1040.11, IEC60825-1:2001)
Field of view 270 ° 190 ° 270 ° 270 °
Scanning frequency 25 Hz / 50 Hz 25 Hz / 35 Hz / 50 Hz / 75 Hz - 25 Hz
Angular resolution 0.25 °
0.5 °
0.25 °
0.5 °
1 °
- 0.5 °
Operating range 0.5 m ... 20 m 0 m ... 80 m 0.05 m ... 4 m 0 m ... 10 m

Max range with 10%

reflectivity

18 m 26 m 2 m 4.5 m
amount of evaluated echoes 2 2 - -
Fog correction Yes No - -
Response time ≥ 20 ms ≥ 13 ms Typ. 134 ms -
detectable object shape Almost any Almost any Almost any Almost any (diameter: 30 mm, 40 mm, 50 mm, 70 mm, 150 mm (selectable))
Systematic error ± 30 mm ± 25 mm (1 m ... 10 m)
± 35 mm (10 m ... 20 m)
± 40 mm -
Statistical error ± 12 mm ± 7 mm (1 m ... 10 m)
± 9 mm (10 m ... 20 m)
- -
Integrated application Field evaluation Field evaluation Field evaluation Field evaluation
Number of field sets 10 fields 4 fields 1 field pair (2 fields) 1 field pair (2 fields)
Simultaneous processing cases 10 4 1 (2fields) 1 (2 fields)
Serial (RS-232) Yes - Yes Yes
Function (Serial (RS-RS-232)) Host, Aux - - -
Data transmission rate (Serial (RS-232)) 9.6 kBaud ... 115.2 kBaud - - -
Ethernet: Yes Yes - -
Function (Ethernet): Host Host - -
Data transmission rate (Ethernet): 10/100 Mbit 10/100 Mbit   -
Protocol ethernet TCP/IP, OPC TCP/IP, OPC - -
CAN bus Yes - Yes Yes
Function (CAN bus) Outputs extension - - -
PROFIBUS DP - - - -
PROFINET - - - -
DEVICENET - - - -
Switching inputs 2 2 4 1
Switching outputs 3 3 3 (plus 1 x "device ready") 2
Optical indicators 1 7-segment display (plus 5 LEDs showing device status, contamination warning and initial condition) 5 LEDs (additional 7-segment display) 2 LEDs (ON, switching status) 1 7-segment display (contamination warning, initial condition)
Electrical connection 1 system plug with screw terminal block 5 LEDs (additional 7-segment display) 2 LEDs (ON, switching status) 1 system plug with screw terminal block
Operating voltage 1 system plug with screw terminal block 24 V DC 10 V DC ... 28 V DC 16.8 V DC ... 30 V DC
Power consumption 20 W 22 W Typ. 3 W, without output load 8 W
Housing color Light blue (RAL 5012) Light blue (RAL 5012) Light blue (RAL 5012) Black (RAL 9005)
Enclosure rating IP 65 (EN 60529, Section 14.2.5) IP 65 (EN 60529, Section 14.2.7) IP 65 (EN 60529/A1:2000-02) IP 65 (EN 60529, Section 14.2.5)
Protection class III (EN 50178 (1997;10)) III (EN 60529, Section 14.2.7) III (EN 60950-1/A11 (2009-03)) II (VDE 0106, EN50178)
Weight 1.1 kg, without connecting cables 3.7 kg 150 g, without connecting cables 1.2 kg, without connecting cables
Dimensions 105 mm x 102 mm x 152 mm 160 mm x 155 mm x 185 mm 60 mm x 60 mm x 79 mm 105 mm x 102 mm x 152 mm
Object remission 2 % ... > 1,000 % (reflectors) 2 % ... > 1,000 % (reflectors) 4 % ... > 1,000 % (reflectors) 1.8 % ... > 1,000 % (reflectors)
Electromagnetic compatibility (EMC) EN 61000-6-2:2005 / EN 61000-6-4 (2007-01) EN 61000-6-2:2005 / EN 61000-6-3 (2001-10) EN 61000-6-3 (2007-01) / EN 61000-6-2 (2005-08) -
Vibration resistance EN 60068-2-6 (1995-04) EN 60068-2-6 (1995-04) EN 60068-2-6 (2008-02) -
Shock resistance EN 60068-2-27 (1993-03) EN 60068-2-27 (1993-03) / EN 60068-2-29 (1993-04) EN 60068-2-27 (2009-05) -
Ambient operating temperature 0 °C ... 50 °C 0 °C ... 50 °C -10 °C ... 50 °C -10 °C ... 50 °C
Storage temperature -30 °C ... 70 °C -12 °C ... 50 °C -30 °C ... 70 °C -30 °C ... 70 °C
Ambient light safety 40,000 lx 70,000 lx 15,000 lx -