5-meter range,
12 / 24VDC, 25ms/scan,
+/-40mm 270o scan angle,
USB / RS422 interface (Measurement / Logging Data type – SCIP Protocol)
Hokuyo UST-05LA specifications
UST-05LA Specifications
Format | UST-05LA |
---|---|
Light Source | Semiconductor laser λ = 905nm, laser safety class 1 |
Supply Voltage | (10% within 10 ~ 30V ripple operating voltage range) DC12V/24V |
Power consumption | 150mA or less, but (DC24V), and about 300mA need inrush current during start-up |
Detection Range and Detection width | 0.06 ~ 5m detection guaranteed value (white Kent paper) 0.06 ~ 2M (10% reflectance at the time) |
Accuracy | ±40mm1 |
Measurement Resolution andRepeated Accuracy | sigma <20mm1 |
Scan time | 25msec (motor rotational speed 2400rpm) |
Scan Angle | 270º |
Angular Resolution | 0.5º |
Interface | RS422 |
Ambient Condition(Temperature, Humidity) | -10ºC ~ +50ºCLess than 85%RH (Without Dew, Frost) |
Vibration Resistance | 2 hours each 10 ~ 55Hz double amplitude 1.5mm XYZ direction 55 ~ 200 Hz 98m / s 2 1 hour each XYZ direction sweep 2 minutes |
Protective Structure | Optics: IP65 |
Weight | 130g (excluding cable) |
External Dimension(W×D×H) | 124mm×126mm×150mm (ecluding connector |
1. Precision is the precision reference reflecting plate by the reference environment at the time of shipment by the (white Kent paper).